Merlin Powerlift Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
EDR4 1169 G 10/03
12
Additional setup for trackless tilt
doors (jamb fittings) only
The aim of these steps is to make the opener push in the direction that the door edge is
moving. Preferably the door edge is being forced upward slightly as the closing cycle begins.
You must adjust the top limit of travel so that if you sight along the fully open door the sight
line intersects the pole in front of the trol-
ley - not behind the trolley.
If the door does not open far enough af-
ter setting the top limit of travel correctly
then it will be necessary to make some
installation changes. You will need to try
some or all of: raising the location of the
header bracket further, lowering the power
head further or increasing the length of
the door arm further.
WARNING The door is not safe for un-
supervised operation until the force sensitivity has been be set.
Setting the force sensitivity
STEP 1: Remove the lamp cover by turning the catch on its underside. Remove the green
control panel cover.
STEP 2: Identify the green and the red control knobs marked open-force and close-force.
Note: The opener can be set to either determine its own safe operating force level, or it can
Opener position and open
door position for trackless
tilt door
exit delay
Light door
roller: L
tall door
auto-
close
on
on
R
on
short
long
open
auto
open
force
operate
learn delete
close
auto
close
force
program
remove
for setup
manual
control
Sight line intersects pole
in front of the trolley
STEP 3: Press and hold the green operate button to move
the door up and down into the required fully open or fully
closed positions. Each time the operate button is pressed
the door will stop or move in the opposite direction.
STEP 4: When the door is at the fully closed position, turn
the down-limit screw (located adjacent to the courtesy lamp)
until the red close-LED stays on continuously.
STEP 5: When the door is at the fully open position, turn
the up-limit screw (located adjacent to the courtesy lamp)
until the green up-LED stays on continuously.
STEP 6: If the door can not be moved sufficiently far then
look at the red and green LEDs. If one of these is on con-
tinuously then the door has stopped at a limit point. Adjust
that limit to allow more travel. One turn of a limit adjust-
ment screw results in 250mm of door travel.
Seitenansicht 11